A & E Lab – Dental Autoclave

What is class B & class N autoclave? 
The class B autoclave has vacuum cycle.It is the highest class autoclave,which is conforming to the most stringent demands and therefore can be unrestrictedly used for the sterilization of all possible loads for all kinds of sterilization packaging (solid ,hollow road type A and hollow road instruments with wrapped and unwrapped). A “class B” autoclave must in any case pass a Helix test as per EN 13060 by test body per EN 867-5:2001. According to expert opinion, that can only be achieved with a fractionated pre-vacuum procedure. Post vacuum drying provides complete drying of porous loads and hollow instruments at the end of thesterilization process. The class N autoclave do not have vacuum cycle. If you only sterilize unwrapped non hollow instruments, you only need an autoclave capable of running class N cycles.

What is the standard of EN 13060? 
This European Standard specifies the performance requirements and test methods for small steam sterilizers and sterilization cycles which are used for medical purposes or for materials that are likely to come into contact with blood or body fluids. This European Standard applies to automatically controlled small steam sterilizers that generate steam using electrical heaters or use steam that is generated by a system external to the sterilizer.

Model number 
The first letter of the model number means class N type or class B type autoclave. The Arabic numerals in the model number means the capacity of the autoclave. The last letter of the model number means the which series of our autoclave.

Technical Specifications

Class Type Class B Series Class N Series
Model AE-C18B1 AE-C23B1 AE-C18N1 AE-C23N1
Volume 18 liter 23 liter 18 liter 23 liter
Chamber size Ø247×350mm Ø247×450mm Ø247×350mm Ø247×450mm
Power 2200W 2200W 2100W 2100W
Net weight 47kgs 51kgs 45kgs 48kgs
Optional: 1.Printer  2. USB port and USD stick   3. Double door locking device

4. Independent Drying program

 

Class N Autoclave

Program Temp (°C) Pressure (Mpa) Sterilization Time (Min) Total Time (min)
Solid 134 210 4 20-45
121 110 20 35-60
Liquid 134 210 10 35-60
121 110 30 35-60
Wrapped 134 210 10 45-65
121 110 30 50-75
Textile 134 210 10 45-65
121 110 30 50-75
Prion 134 210 18 45-75
Druing —– —– —– 1-20

 

Documentation

Internal printer printsdetailed sterilization data automatically in multiple languages;
2. A USB port is used for connecting a usb stick, all sterilization data are automatically written in the usb

stick and can be read directly in any pc and stored electronically;
3. The last 20 cycles can be automatically stored in the Autoclave system.

Which can be printed out at any time.

Model Type Power Chamber Volume
AE-C18N2 Class N 2100W 18 Liters
AE-C18B2 Class B 2200W 18 Liters
AE-C23N2 Class N 2100W 23 Liters
AE-C23B2 Class B 2200W 23 Liters

 

Chamber Out Size
Ø247×350 W 480mm/H 455mm/D 600mm
Ø247×350 W 480mm/H 455mm/D 600mm
Ø247×450 W 480mm/H 455mm/D 700mm
Ø247×450 W 480mm/H 455mm/D 700mm